Voltage Inspection
NOTE:
The variable tumble shutter valve switch cannot be removed as a single unit. When replacing the variable tumble shutter valve switch, replace it together with the intake manifold as a single unit.
1. Connect the M-MDS to the DLC–2.

2. Switch the ignition to ON.
3. Verify that the variable tumble shutter valve switch output voltage (PID: IMRC_POS) is within the specification..
If not as specified, replace the intake manifold..
Throttle Position (TP) Sensor Inspection [Mzr 2.0, Mzr 2.5]